OWNER'S MANUAL
SPECIFICATIONS
BTU (Variable)
Type Gas
Ignition
Pressure Regulator Setting
Inlet Gas Pressure (in. of water) *
Maximum
Minimum
Dimensions, Inches (H x W x D)** Heater
Carton
Weight (pounds)
Heater
Shipping
•Forpurposesof input adjustment •*Measurementincludesknobsand hood.
TECHNICAL
SERVICE
You may have further questions about in- stallation, ol_ration, or troubleshooting.
If so, contact DESA International's Techni- cal Service Department at
15,000/30,000
Propane/LP Only
Piezo
8" W.C.
14"
11"
23.75x 25.9 x 8.5 26 x 27.75 x 10.25
29
35
SERVICE HINTS
When gas pressure is too low
•pilot will not stay lit
•burner will have delayed ignition
•heater will not produce specified heat
•propane/LP gas supply may be low
When gas quality is bad
•pilot will not stay lit
•burner will produce flames and soot
•heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your local prnpane/LP gas supplier.
REPLACEMENT
PARTS
Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.
Parts Under Warranty
Contact authorized dealers of this product. If they can't supply original replacement part(s), either contact your nearest Parts
Central (see below) or call DESA
International's Technical Service Depart- ment at
When calling DESA International, have ready:
•your name
•your address
•model number of your heater
•how heater was malfunctioning
•type of gas used (propane/LP or natural gas)
•purchase date
Usually, we will ask you to return the defec- tive part to the factory.
Parts Not Under Warranty
Contact authorized dealers of this product. If theycan 't supplyoriginal replacement part(s), either contact your nearestParts Central (page
20)or call DESA International's Parts De- partment at
When calling DESA International, have ready:
•model number of your heater the replacement part number
_o44_ | 19 |