Digi m10 Technical Overview

4.3Temperature Query Response

The Temperature Query Response packet (see Table 4) is sent from the Digi m10 to the host controller, indicating the satellite modem’s temperature in degrees Celsius.

Table 4: Temperature Query Response Packet

0

0x05/0x06

Packet Header

 

 

 

1

0x1A

Packet Type

 

 

 

2

Length0

Length of the packet

 

 

 

 

 

3

Length1

 

 

 

 

4

Retry_count/ Pkt Sequence Number

 

 

 

 

5

Temp0

Temperature value in

 

 

little endian

 

 

format.(This is a 32

6

Temp1

bit floating point

 

 

 

 

number)

7

Temp2

 

 

 

 

8

Temp3

 

 

 

 

9

Fletch0

Fletcher Checksum

 

 

 

10

Fletch1

 

 

 

 

NOTE: This packet is sent from the Digi m10 to DTE and it contains the current temperature of the Digi m10 in degrees Celsius.