DIRECT - Cabinet Off

 

 

1X12

1 - 1x12 Mic 1

4X12V

1 - 4x12 Vintage Mic 1

1X12

2 - 1x12 Mic 2

4X12V

2 - 4x12 Vintage Mic 2

1X12

3 - 1x12 Mic 3

4X12V

3 - 4x12 Vintage Mic 3

1X12

4 - 1x12 Mic 4

4X12V

4 - 4x12 Vintage Mic 4

2X12o

1

- 2x12 Open Back Mic 1

4X12B 1 - 4x12 British Mic 1

2X12o

2

- 2x12 Open Back Mic 2

4X12B 2 - 4x12 British Mic 2

2X12o

3

- 2x12 Open Back Mic 3

4X12B 3 - 4x12 British Mic 3

2X12o

4

- 2x12 Open Back Mic 4

4X12B 4 - 4x12 British Mic 4

2X12c

1

- 2x12 Closed Back Mic 1

4X12G

1 - 4x12 Green Mic 1

2X12c

2

- 2x12 Closed Back Mic 2

4X12G

2 - 4x12 Green Mic 2

2X12c

3

- 2x12 Closed Back Mic 3

4X12G

3 - 4x12 Green Mic 3

2X12c

4

- 2x12 Closed Back Mic 4

4X12G

4 - 4x12 Green Mic 4

The following diagram shows the difference between the Mic 1 through Mic 4 selections:

EQ

Equalization is an extremely useful tool used to further shape the tonal response of your guitar signal. The EQ in the RP300A is similar to the tone knobs on an amplifier. All three EQ parameters range from -12dB to +12 dB.

EQ On/Off - The Number 1 Knob turns the EQ on (ON) and off (OF). Bass - The Number 2 Knob adjusts the amount of low end enhancement.

Mid Frequency - The Number 3 Knob selects the frequency to which the boost will be applied by the mid level knob. Ranges from 500Hz (500 Hz.) to 3000Hz (3000 Hz.)

Mid Level - The Number 4 Knob adjusts the amount of mid range enhancement. Treble - The Number 5 Knob adjusts the amount of high end enhancement.

Noise Gate

A Noise Gate is designed to eliminate hiss and ambient noise while you are not playing. A Noise Gate can also be used to create an automatic swell in volume. The RP300A includes two different types of Noise Gates: Silencer™, and Pluck. The Silencer™ operates as a standard Noise Gate. The Pluck Noise Gate is designed to close after every note (depending on the Pluck Sensitivity). This allows automatic volume swells to occur on a note for note basis.

Gate On/Off - The Number 1 Knob turns the Noise Gate on (ON) and off (OF).

Gate Type - The Number 2 Knob selects between the silNCR (Silencer ™) or PLUCK (Pluck) type of Noise Gates.

Gate Attack - The Number 3 Knob adjusts the length of time it takes the gate to open once the Threshold has been exceeded before the signal becomes audible. Ranges from 1 (immediate signal), to 9 (Selects the Auto Swell volume swell effect. This setting will gradually ramp up the volume).

12

Page 16
Image 16
DigiTech RP300A manual Noise Gate