Dimplex DF2603 manual New Wall Construction

Models: DF2603

1 15
Download 15 pages 33.19 Kb
Page 6
Image 6
FIGURE￿5

12”

CORD

3

FIGURE￿5

23”

26￿1/2”

FIGURE￿3

FIGURE￿4

OUTLET

NOTE 1

A 15 Amp, 120 Volt circuit is required. A dedicated circuit is preferred but not essential in all cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or fuse blows on a regular basis when the heater is operating. Additional appliances on the same circuit may exceed the current rating of the circuit breaker.

WARNING

To prevent personal injury you should hire a professional to cap the chimney flue or cut a hole in the existing fireplace for wiring.

·If you return your existing fireplace to its original use (Example: Wood Burning). it should be inspected by the local building department prior to use to reduce the risk of fire and injury to persons .

￿New Wall Construction:

1.Select a suitable location that is not susceptible to moisture and is away frorn drapes. furniture and high traffic.

2.Place the Fireplace in the desired location to see how it will look in the room.

3.Mark the desired location on the floor and store the Fireplace in a safe, dry and dust free location.

4.Use studs to frame an opening of 261/2" wide X 23" high (67.3cm wide X 58.4crn high) allowing a depth of 12· (30.5cm). (Refer to FIGURE 3 as an example.)

5.Plan your electric power supply: (Refer to Note 1)

Option #1 - The power cord can be lead from behind the trim and along the wall to an outlet near the fireplace. (FIGURE 4)

Option #2 - A new outlet can be installed inside the new frame construction. (FIGURE 5)

Page 6
Image 6
Dimplex DF2603 manual New Wall Construction