Dimplex VCX1525-WH owner manual Bathroom Installation, Fireplace Installation

Models: VCX1525-WH VCX1525

1 20
Download 20 pages 62.23 Kb
Page 13
Image 13
Bathroom Installation

Manual background Fireplace Installation

Fireplace

Junction

Box

White wire (N)

Black wire (L)

Green wire (G)

White wire (N)

Black wire (L)

Green wire (G)

120 V Power

Supply

(Breaker Panel)

fasteners. Attach supplied wall cover brackets to the top and the bottom of fireplace to cover the gap on the dry wall (Figure 8).

Attach fireplace frame as shown in Figure 4.

Bathroom Installation

This firebox must be protected by a GFI receptacle or circuit for bathroom use. If receptacle

Figure 8

Add wood screws here

is used it must be readily accessible.

This unit is an electrical appliance that is not watertight and must be installed as to prevent water from entering the unit to prevent electrical shock. This unit must be installed away from showers, tubs, etc.

Never locate fireplace where it may fall into a bathtub or other water containers. Keep towels and other combustible materials three (3) feet (0.9 m) away from the bottom of the unit.

The controls are located on the right hand side of the fireplace (Figure 9).