Check the oil level in hydrostatic transmission oil reservoir after every 25 hours of usage. Clean the oil reservoir cap and the area around it prior to removal. Check the oil level. Oil should be approximately ¼” below top of oil tank baffle. Replenish as needed with 15W-50 Synthetic Hydrostatic Oil or a quality SAE 20W-50 motor oil. DO NOT OVERFILL. When checking the oil level, be very careful to keep the reservoir clean.

Change the oil in the reservoir and hydrostat transmission oil filter after the first 100 hours of use and then every 500 hours. Remove the filter and be sure all oil has drained from the reservoir. Replace with a new OEM filter

(P/N 539 121763) and 15W-50 Synthetic Hydrostatic Oil or a quality SAE 20W-50 motor oil.

¼" (6mm)

 

È

 

Ç

Baffle

Oil Level

 

Fig. 13

Please dispose of used oils at proper collection centers.