TROUBLESHOOTING

ELECTRICAL SYSTEM:

 

 

SITUATION

CAUSES

REMEDY

Starter will not

Circuit breaker engaged

Push button to reset

turn engine over

 

Consult your dealer for repair

Starter will not

Dead battery

Charge battery

turn engine over

 

 

 

Poor connections on

Tighten or replace as required

 

 

 

battery

 

 

Battery water low

 

 

Wrong battery installed

 

 

in mower

 

Battery discharge

Battery discharge

Engine electrical system

Have electrical system checked by

not functioning correctly

your dealer

Engine being operated

Increase engine RPM

at too low an RPM

Contact your dealer for information

NOTE: Electrical system failures ar e generally simple in nature, always check the obvious first and then move onto the more complicated parts used. Poor battery service, loose connections, corrosion, frayed or broken wiring, are more likely than component failure.