DMP Electronics XR6A Annunciator Outputs, Telephone RJ Connector, 12.1Description, Color, Wire

Models: XR10A XR6A XR20A

1 18
Download 18 pages 62.18 Kb
Page 16
Image 16
Annunciator Outputs

Installation

Annunciator Outputs

12.1Description

The four annunciator outputs can be programmed to indicate the activity of the panel's zones or conditions occurring on the system. Annunciator outputs do not provide a voltage but instead switch to ground voltage from another source. The outputs can respond to any of the conditions listed below:

1)Activation by zone condition: Steady, Pulse, Momentary, or Follower

2)Manually from the Security Command keypad

3)Communication failure

4)Armed area annunciation

5)Fire Alarm or Fire Trouble

7)Ambush alarm

8)Exit and Entry timers

9)System Ready

10)Ground start activation

12.2Harness wiring

The open collector outputs are accessible by installing the DMP 300 Harness on the 4-pin header labeled J11. The output locations are shown below:

Output

Color

Wire

1

Red

1

2

Yellow

2

3

Green

3

4

Black

4

Telephone RJ Connector

13.1Description

Connect the panel to the public telephone network by installing a DMP 356 RJ Cable between the panel's J4 connector and the RJ31X or RJ38X phone jack.

Phone Cable Monitor

A two pin header labeled RJ SUP (J7) is provided to allow monitoring of the telephone cable connected between the panel and a RJ38X jack (pins 2 & 7 jumpered). Attach a DMP Model 306 Harness between J7 and any available zone. The pins of J7 are connected via the telephone cable to 2 & 7 of the RJ38X jack. The RJ38X jack provides a jumper between pins 2 & 7 which completes the circuit.

When the zone is programmed for a Supervisory type (SV) and the telephone cable is removed, the keypad will display the zone in trouble and produce a steady tone.

13.2ACA Compliance

The XR6A/XR10A/XR20A have been tested and meet the requirements of ACA Technical Standard TS-002-1997 for Telecommunications.

13.3Ground start

To configure the XR6A/XR10A/XR20A for ground start operation, you must install the appropriate ground start module and program one of the panel's available annunciator outputs for Ground Start operation. Refer to the XR6A/XR10A/XR20A Programming Guide for complete programming information.

XR6A/XR10A/XR20A Installation Guide

Digital Monitoring Products

2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282

Page 12

Page 16
Image 16
DMP Electronics XR6A Annunciator Outputs, Telephone RJ Connector, 12.1Description, 12.2Harness wiring, 13.1Description