Introduction
Panel Specifications
1.1Power supply
Transformer Input: 16.5 VAC 40VA or 16.5 VAC 20VA
Standby Battery: 12 VDC 7.0Ah (40VA transformer charges up to 2 batteries)
Auxiliary Output: 12 VDC at 500mA
Bell Output: 12 VDC at 1.5 Amps with 40VA transformer, 600mA with 20VA transformer
Smoke Detector Output: 12 VDC at 100mA All circuits inherent power limited
1.2Communication
All panels can operate as a local system.
1.3Panel zones
Nine 1k W EOL burglary zones (zones 1 to 9), (zones 1 to 5 on XR6A)
One 3.3k W EOL Class B powered fire zone with reset capability (zone 10 on XR10A and XR20A), (zone 6 on XR6A)
1.4Keypads
You can connect up to four of the following supervised keypads to the XR6A/XR10A/XR20A panels.
•16 or 32 character alphanumeric keypads
•
In addition, four and single point zone expanders can be added to the XR20A panel.
When using the FA426 Wireless Receiver, the XR20A allows unsupervised devices to be added to address five.
1.5Outputs
The XR6A/XR10A/XR20A panels provide four open collector outputs rated for 50mA each. See section 12.1. A Model 300 Wire Harness is required. The open collector outputs provide the ground connection for a positive voltage source.
1.6Enclosure specifications
The XR6A/XR10A/XR20A panel ships in an enclosure with EOL resistors, battery leads, user's guide, and programming sheet.
Size: | 12.5" W x 9.5" H x 2.75" D |
Weight: | 4 lbs |
Color: | Gray or Black |
Construction: | 20 gauge cold rolled steel |
XR6A/XR10A/XR20A Installation Guide
2841 E. Industrial Drive Springfield, MO USA | Digital Monitoring Products |