DMP Electronics XR10A, XR20A Reset Jumpers J16, Troubleshooting Section, 14.1Description, Problem

Models: XR10A XR6A XR20A

1 18
Download 18 pages 62.18 Kb
Page 17
Image 17
Reset Jumpers J16

Installation

Reset Jumpers J16

14.1Description

There are two reset jumpers located at the top right of the panel's circuit board labeled RESET. Momentarily shorting these jumpers allows you to reset the microprocessor of the XR6A/XR10A/XR20A. Resetting the panel allows you to enter the panel's internal programmer.

To reset the panel when first installing the system, place the blade of a slotted screwdriver across the two reset jumpers after applying power to the panel.

To reset the panel while the system is operational (for example, prior to reprogramming), you can short the jumpers without powering down the system.

After resetting the panel for programming, you must begin within 30 minutes. If you wait longer than 30 minutes, you'll have to reset the panel again.

Troubleshooting Section

15.1Description

This section of the XR6A/XR10A/XR20A Installation Guide provides troubleshooting information for use when installing or servicing an XR6A/XR10A/XR20A system.

Problem

Possible Cause

Solution

 

 

 

 

J16 reset jumper is installed.

Remove the J16 reset jumper.

Security Command keypads

Open or short on the green data

Check for broken or shorted wires

wire to the keypad.

between the keypad and panel.

display " SERVICE REQUIRED"

Bad keypad or zone expander.

Replace with a new or repaired

 

 

 

keypad or zone expander.

 

 

 

Keypad display is not functional.

Open or short condition on the

Check for broken or shorted

yellow data wire.

wires.

When a key is pressed, only a

 

 

short beep is emitted.

Bad keypad or zone expander.

Replace with a new or repaired

 

 

keypad or zone expander.

 

 

 

Keypad beeps when keys are

Two or more keypads are assigned

Set each keypad to a different

pressed but won't allow the user

address to match the Device

to the same address.

to arm or enter the User Menu.

Setup programming.

 

 

 

 

XR6A/XR10A/XR20A Installation Guide

2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282

Digital Monitoring Products