HVAC System Powered

ENGLISH

DC Wiring

AC Wiring

Alternator

120VAC Line

HVAC Unit

HVAC System Powered

Battery-Powered

Start

Start

Battery 1

Battery 2

-

+

-

+

NOTES:

Inverter

- +

Battery

Separator

House

Battery 1

- +

House Battery 2

-+

House

Battery 3

-+

House

Battery 4

-+

Overcurrent Protection

by Inverter and separate battery

Systems Installation Guidelines

banks with

 

1)House batteries must be of the AGM dual purpose deep cycle/starting type.

2)Alternator should be upgraded. Discuss with Dometic Applications Department for recommendation.

3)Inverter must be of approved type by Dometic in order to insure proper operation of system.

4)Cable size should be chosen based on voltage drop and load. Cable to inverter should be 2/0 gauge or greater. All cables should have an ampacity rating of greater than the expected amp flow and/or the overcurrent protection device.