Dometic 2597 shorepower capability, HVAC System Powered by Inverter -single, starting/house, bank

Models: 2597

1 20
Download 20 pages 8.85 Kb
Page 20
Image 20
shorepower capability

ENGLISH

DC Wiring

AC Wiring

Alternator

120VAC Line

HVAC Unit

Shorepower Inlet

shorepower capability

HVAC System Powered by Inverter -single

Battery-Powered SystemsInstallation

Battery 1

Battery 2

Battery 3

Battery 4

-

+

-

+

-

+

- +

NOTES:

Battery 5

-+

Battery 6

-+

Overcurrent Protection

+-

Inverter with Shorepower Pass-Thru Capability OR Inverter/Charger

starting/house

Guidelines

battery

 

1)House batteries must be of the AGM dual purpose deep cycle/starting type.

2)Alternator should be upgraded. Discuss with Dometic Applications Department for recommendation.

3)Inverter must be of approved type by Dometic in order to insure proper operation of system.

4)Cable size should be chosen based on voltage drop and load. Cable to inverter should be 2/0 gauge or greater. All cables should have an ampacity rating of greater than the expected amp flow and/or the overcurrent protection device.