Shorepower

16

DC Wiring

AC Wiring

Cab Power

AlternatorOutlets

120VAC Line

Y-Cord

Splitter

- +

HVAC Unit

Shorepower Inlet

Inverter with Shorepower Pass-Thru Capability OR Inverter/Charger

Shorepower

HVAC System

and cab power outlets

Powered by Inverter and

Battery-

Start

Start

Battery 1

Battery 2

-

+

-

+

NOTES:

Battery Separator

House

Battery 1

-+

House Battery 2

-+

House

Battery 3

-+

House

Battery 4

-+

Overcurrent

Protection

Powered Systems

1)House batteries must be of the AGM dual purpose deep cycle/starting type.

2)Alternator should be upgraded. Discuss with Dometic Applications Department for recommendation.

ENGLISH

3)Inverter must be of approved type by Dometic in order to insure proper operation of system.

4)Cable size should be chosen based on voltage drop and load. Cable to inverter should be 2/0 gauge or greater. All cables should have an ampacity rating of greater than the expected amp flow and/or the overcurrent protection device.