REMOVING AND REPLACING FEED BELT
DISCONNECT MACHINE FROM POWER SOURCE.
1.Disconnect the DC Motor Quick Connect. (see Fig. 10).
2.Use a 1/4" hex wrench to remove the four table mounting screws, lockwashers and flange nuts , two of which are shown at (A) Fig. 32.
3.Remove the table, and place it on a firm supporting surface.
4.Loosen the two socket head set screws (D) Fig. 33A and Fig. 33B equally at each side of the table until tension is relieved on roller (E). NOTE: Count the number of turns as you loosen the screws.
5.Slide the feed belt (A) Fig. 34, off table (B). Place the new feed belt on the table and
6.Attach the table (F) Fig. 33A, to the support plate and adjust the tension and tracking on the feed belt. Refer to section “CHECKING
AND ADJUSTING TRACKING AND TENSION ON THE FEED BELT” in this manual.
DUST COLLECTION
The drum cover has a 4” O.D. dust chute (A) Fig. 35 that connects to a dust collection system.
NEVER OPERATE THIS MACHINE WITHOUT FIRST CONNECTING IT TO A DUST COLLECTION SYSTEM. It is recommended that a dust collection system be used with at least 400 to 600 CFM capacity.
Attach a 4" hose to the hood, or attach an accessory dust collector elbow (B) Fig. 35 to the dust chute (A). Attach the dust collection system to the elbow (B).
FOR OPERATOR SAFETY, NEVER PUT FINGERS OR ANY OTHER FOREIGN OBJECT IN THE DUST CHUTE.
AA
Fig. 32
D
B
FD E
Fig. 33A
D
Fig. 33B
BA
Fig. 34
B
A
Fig. 35