8. LONG TERM STORAGE OF YOUR HEATER

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

TO STOP HEATER

1.Turn switch to “OFF” and unplug power cord.

TO RESTART HEATER

1.Wait 10 seconds after stopping heater.

2.Repeat steps under to start heater.

8. LONG TERM STORAGE OF YOUR HEATER

1.Drain fuel tank through fuel cap opening.

2.Using a small amount of kerosene, swirl and rinse the inside of the tank.

NEVER mix water with the kerosene as it will cause rust inside the tank. Pour the kerosene out making sure that you remove it all.

IMPORTANT: Do not store kerosene over summer months for use during next heating season. Using old fuel could damage heater.

-Reinstall fuel cap. Properly dispose of old and dirty fuel.

-Store heater in dry well ventilated area. Make sure storage place is free of dust and corrosive fumes.

-Store the heater in the original box with the original packing material and keep the USER’S MANUAL with the heater.

9.MAINTENANCE

WARNING!!: NEVER SERVICE HEATER WHILE IT IS PLUGGED IN OR WHILE HOT!

USE ORIGINAL EQUIPMENT REPLACEMENT PARTS. Use of third party or other alternate components will void warranty and may cause unsafe operating conditions.

A.) FUEL TANK

FLUSH EVERY 200 HOURS OF OPERATION OR AS NEEDED (SEE STORAGE ABOVE)

B.) AIR INTAKE FILTER

WASH AND DRY WITH SOAP AND WATER EVERY 500 HOURS OF OPERATION OR AS NEEDED.

-Remove screws along each side of heater using medium phillips screwdriver

-Lift upper shell off.

-Remove fan guard.

-Wash or replace air intake filter.

-Reinstall fan guard and upper shell.

Upper Shell

Air Intake Filter

Fan Guard

Figure 10

9