Dyna-Glo RMC-KFA45T I. Pump Pressure Adjustment, Never Leave The Heater Unattended While Burning

Models: RMC-KFA45T, RMC-KFA65T, RMC-KFA120T, RMC-KFA170T, RMC-KFA210T RMC-KFA65T RMC-KFA210T RMC-KFA45T

1 28
Download 28 pages 6.3 Kb
Page 16
Image 16
I.) PUMP PRESSURE ADJUSTMENT

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

I.) PUMP PRESSURE ADJUSTMENT

-Remove pressure gauge plug from end filter cover.

-Install accessory pressure gauge.

-Start heater (See Operation, page 8)

Allow motor to reach full speed

-Adjust pressure (Using a flat blade screwdriver) Turn relief valve to right to increase pressure. Turn relief valve to left to decrease pressure. Set pump pressure below correct for pressure for each model.

-Stop heater (See Operation, page 9)

-Remove pressure gauge. Replace pressure gauge plug in end filter cover.

MODEL

PUMP PRESSURE

RMC-KFA45T

2.8 psi

RMC-KFA65T

3.5 psi

RMC-KFA120T

4.5 psi

RMC-KFA170T

6.5 psi

RMC-KFA210T

8.5 psi

 

 

Pressure Gauge

Plug

Relief Valve

Pressure Gauge

NOTE: USE ONLY ORIGINAL EQUIPMENT REPLACEMENT PARTS.

Use of alternate or third party components will void any warranty and may cause unsafe operation condition.

15

Page 16
Image 16
Dyna-Glo RMC-KFA45T, RMC-KFA210T, RMC-KFA65T I. Pump Pressure Adjustment, Never Leave The Heater Unattended While Burning