I) FUEL VALVE

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

I) FUEL VALVE

( For RMC-KFA210T Model only)

-Remove side cover screws using medium phillips screwdriver (See page 13).

-Remove upper shell (See page 9).

-Remove fan (See page 10).

-Pull fuel line (lower and upper) off the fuel valve fittings (See figure 21).

-Disconnet red and orange wires from valve connector (See figure 21).

-Remove 2 screws holding fuel valve and bracket to lower shell Using medium phillips screw driver (See figure 21).

-Remove 2 screws holding fuel valve to Bracket using medium phillps screw driver.(See figure 21).

-Attach new fuel valve to bracket with 2 screws.

-Install new fuel valve and bracket on lower shell with 2 screws.

-Connect red and orange wires (polarity not important) to valve connector (See figue 21).

-Connect upper and lower fuel lines to fuel valve (See figure 21).

-Replace fan, upper shell, side cover.

Electrical Wire

Valve Connector

 

 

Fuel Line

 

Hose Upper

Adaptor Nozzle

 

Fuel Line

Screw

Hose Lower

 

 

Screw

 

Bracket

 

Valve

 

Valve

 

Fittings

 

Low shell

Figure 21.