Dyna-Glo RMC-KFA45T, RMC-KFA210T F. Spark Plug, Never Leave The Heater Unattended While Burning

Models: RMC-KFA45T, RMC-KFA65T, RMC-KFA120T, RMC-KFA170T, RMC-KFA210T RMC-KFA65T RMC-KFA210T RMC-KFA45T

1 28
Download 28 pages 6.3 Kb
Page 12
Image 12
F.) SPARK PLUG

NEVER LEAVE THE HEATER

UNATTENDED WHILE BURNING!

(For RMC-KFA 210T Model Only)

-Remove upper shell (See page 9).

-Remove fan (See page 10).

-Remove fuel and air line hoses from adaptor-nozzle.

-Remove ignitor wire from spark plug.

-Remove photocell from photocell bracket.

-Remove combustion chamber.

-Remove four screws using medium phillips screwdriver and remove bracket-burner from combustion chamber.

-Remove spark plug from burner head using medium phillips screwdriver.

-Carefully remove nozzle from adaptor-nozzle using 5/8” socket wrench.

-Blow compressed air through face of nozzle. (this will remove any dirt in nozzle)

-Reinstall nozzle into adaptor-nozzle and tighten firmly. (80~110 inch-pounds)

-Reinstall spark plug in bracket-spark.

-Attach Bracket-Burner to combustion cahmber.

-Replace combustion chamber.

-Attach ignitor wire to spark plug.

-Attach fuel and air line hoses from adaptor-nozzle.

-Attach photocell to photocell bracket.

-Reinstall fan blade and upper shell.

Combusion chamber

Bracket Burner

Screw

Bracket Spark

Photo Cell bracket

Photo Cell

Spark Plug

 

Ignitor Wire

Air Line Hose

Fuel Line Hose

Nozzle Face

Bracket Burner

 

Nozzle

Bracket Spark

 

 

Fuel Line Fitting

Spark Plug

Air Line Fitting

Figure 14.

F.) SPARK PLUG

CLEAN AND REGAP EVERY 600 HOURS OPERATION OR

 

REPLACE AS NEEDED.

 

Gap

(For RMC-KFA 45T/65T/120T/170T Models Only)

Burner

- Remove upper shell (See page 9).

Head

Ignitor

- Remove fan (See page 10).

 

Wire

- Remove ignitor wire from spark plug.

 

 

- Remove spark plug from burner head using medium

 

 

phillips screwdriver.

 

 

- Clean and regap spark plug electrodes to 3.5mm gap.

 

 

- Reinstall spark plug in burner head.

 

Spark Plug

- Attach ignitor wire to spark plug.

 

- Reinstall fan and upper shell.

 

Figure 15.

 

 

11

Page 12
Image 12
Dyna-Glo RMC-KFA45T, RMC-KFA210T, RMC-KFA65T user manual F. Spark Plug, Never Leave The Heater Unattended While Burning