Dynacord Professional Power Amplifiers system frequency response in Display, Remote functions

Models: Professional Power Amplifiers

1 72
Download 72 pages 56.54 Kb
Page 21
Image 21
system frequency response in Display

RCM-26

loudspeaker cabinets and systems, factory presets are available with linear phase ‚brick-wall‘ FIR crossovers. These provide users wishing to tune the system themselves with a completely linearized frequency and phase response upon which to build.

system frequency response in Display

For DYNACORD loudspeaker cabinets, measurements of the frequency and phase response are already provided in the IRIS-Net. This data together with the filter, crossover and delay settings conducted in the RCM-26 can be displayed and taken into account by IRIS-Net. The superposition shows the actual frequency response of the loudspeaker cabinet.

Remote functions

Remote control of the power amplifier under IRIS-Net provides Power On / Standby switching and the programming of power-up sequences for the power amplifiers as well as level settings and the muting of

individual channels or channel groups. In the RCM-26, all parameters can be controlled in real time as well as stored in user memories, from which they can be retrieved and reloaded subsequently.

DSP functions

X-over:Linkwitz-Riley, Butterworth, Bessel

FIR Filters: zero latency processing, linear phase X-over

Master EQ: 6 filters per channel; PEQ,

lo-shelf, hi-shelf, hi-pass, lo-pass selectable

Channel EQ: 6 filters per channel; PEQ, lo-shelf, hi-shelf, hi-pass, lo-pass, all-pass selectable

Master delay : 2ms - 2000ms per channel

Channel delay: speaker alignment

Dynamics: compressor, limiter per channel

Protection: Advanced Digital Voice Coil Protection algorithms

Others: input routing, level, mute,

polarity, sine and noise generators, VU meter

21

Page 21
Image 21
Dynacord Professional Power Amplifiers manual system frequency response in Display, Remote functions, DSP functions, RCM-26