Dynacord Professional Power Amplifiers manual DPA 8000 Series, General, 50 V / 20 Ω

Models: Professional Power Amplifiers

1 72
Download 72 pages 56.54 Kb
Page 71
Image 71
50 V / 20 Ω

DPA 8000 Series

DPA 8412

General

 

DPA 8225

 

 

 

 

DPA 8412

 

Load Impedance

50 V / 10 Ω

70 V / 19.6 Ω

 

100 V / 40 Ω

 

50 V / 20 Ω

70 V / 39,2 Ω

100 V / 80 Ω

 

 

 

 

 

 

 

 

 

Rated Output Power, 1kHz, THD < 0.5%

 

250 W

 

 

 

 

125 W

 

 

 

 

 

 

 

 

 

 

Rated RMS Voltage Swing, 1kHz, THD=1%

50 V

70 V

 

100 V

 

50 V

70 V

100 V

 

 

 

 

 

 

 

 

Input Sensitivity, rated power @ rated load, 1kHz

 

 

 

1.55 V (6 dBu)

 

 

 

 

 

 

 

 

 

 

 

Voltage Gain ref. 1kHz

30.2 dB

33.1 dB

 

36.2 dB

 

30.2 dB

33.1 dB

36.2 dB

 

 

 

 

 

 

 

 

 

THD at rated output power MBW=80kHz, 1kHz

 

 

 

 

< 0.5 %

 

 

 

 

 

 

 

 

 

 

 

IMD-SMPTE, 60Hz, 7kHz

 

< 2.0 %

 

 

 

 

< 1.0 %

 

 

 

 

 

 

 

 

 

 

DIM 30, 3,15kHz, 15kHz

 

< 0.2 %

 

 

 

 

< 0.1 %

 

 

 

 

 

 

 

 

 

Max. Input Level

 

 

 

6.15 V (18 dBu)

 

 

 

 

 

 

 

 

 

 

Crosstalk, ref. 1 kHz at rated output power

 

 

 

 

< -80 dB

 

 

 

 

 

 

 

 

 

Frequency Response, ref. 1 kHz, rated load

 

 

 

50 Hz...20kHz

 

 

 

 

 

 

 

 

 

 

Input Impedance, active balanced

 

 

 

 

20 k Ω

 

 

 

 

 

 

 

 

 

 

Signal to Noise Ratio, A-weighted

 

 

 

 

> 102 dB

 

 

 

 

 

 

 

 

 

Output Stage Topology

 

 

 

Class-D, Transformer, Floating

 

 

 

 

 

 

Power Requirements

 

115 V / 230 V AC (-10% / +6%), 50-60 Hz or 24 V DC (-10% / +30%)

 

 

 

 

 

 

 

 

Power Consumption, at rated Output Power

 

 

 

990 W (Mains) / 900 W (Battery)

 

 

 

 

 

 

 

 

 

 

 

Monitor

 

 

 

1.3 V (4.5 dBu)

 

 

- rated Output Voltage

 

 

 

 

 

- rated Load Impedance

 

 

 

 

600 Ω

 

 

 

 

 

 

 

 

 

CAN

 

 

 

10...500 kBit/s, 2 x RJ-45

 

 

 

 

 

 

 

Control Port

 

 

1 x 8-pole Euro Block, 3 Control Inputs/Outputs

 

 

 

2 Reference Outputs (15 V, 100 mA/GND), 1 Ready/Fault Output

 

 

 

 

Protection

Audio Limiters, High Temperature, DC, Short Circuit, Mains Over / Undervoltage Protection,

 

 

DC Supply Undervoltage Protection, Inrush Current Limiter, Ground Fault

 

 

 

 

 

 

 

Cooling

 

 

 

Front-to-Rear, temperature controlled fans

 

 

 

 

 

 

 

 

Ambient Temperature Limits

 

 

 

-5 °C .. +45 °C

 

 

 

 

 

 

 

 

 

 

Safety Class

 

 

 

 

Class I

 

 

 

 

 

 

 

 

 

Dimensions (WxHxD), mm

 

 

 

483 x 88 x 376 mm, 19” / 2 HE

 

 

 

 

 

 

 

 

 

 

 

Weight

 

16 kg

 

 

 

 

18 kg

 

 

 

 

 

 

 

 

 

 