DPA 4000 Series
DPA 4000 Series
technical specifications
General | DPA 4410 | DPA 4411 |
| DPA 4120 | DPA 4140 |
Load Impedance | 100 Ω / 100 V, 50 Ω / 70 V |
| 50 Ω / 100 V, 25 Ω / 70 V | 25 Ω / 100 V, 12.5 Ω / 70 V | |
| 25 Ω / 50 V, 4 Ω / 20 V |
| 12.5 Ω / 50 V, 4 Ω / 28 V | 6.25 Ω / 50 V, 4 Ω / 40 V | |
|
|
|
|
| |
Rated Output Power (Mains) | 4 x 100 W |
| 200 W | 400 W | |
| (acc. to IEC |
| (acc. to IEC | (acc. to IEC | |
| 2 x 200 W configurable |
|
|
| |
| 1 x 200 W + 2 x 100 W configurable |
|
|
| |
|
|
|
|
|
|
Power Output Characteristics |
|
| balanced, floating |
| |
|
|
|
|
| |
Input Characteristics |
|
| balanced |
| |
|
|
|
|
| |
Input Sensitivity |
|
| 775 mV / 0 dBu |
| |
|
|
|
|
| |
Input Impedance |
|
| ≥ 10 kΩ |
| |
|
|
|
|
| |
Distortion @ 1 kHz and Nom. Outp. Power |
|
| ≤ 1 % |
| |
|
|
|
|
| |
Interference Voltage (A) |
|
| ≤ 1.2 mV / |
| |
|
|
|
|
| |
Frequency Response |
|
| 60 Hz .. 20 kHz |
| |
|
|
|
|
| |
Load Impedance (monitor) |
|
| 600 Ω |
| |
|
|
|
|
| |
Nominal Output Voltage (monitor) |
|
| 2 V / + 8.2 dBu |
| |
|
|
|
|
|
|
Output Characteristics (monitor) | unbalanced |
|
| electronically balanced |
|
|
|
|
| ||
Output Stage Topology |
|
| |||
|
|
| |||
Power Requirements |
| 115 V / 230 V AC, ±10 % / 50 - 60 Hz or 24 V DC, | |||
|
|
|
|
| |
Mains Power Consumption | 1010 VA at nominal output |
| 520 VA at nominal output | 1020 VA at nominal output | |
|
|
|
|
| |
| 377 VA driven at |
| 200 VA driven at | 380 VA driven at | |
|
|
|
|
| |
| 62 VA no signal | 67 VA no signal | 30 VA no signal | 44 VA no signal | |
|
|
|
|
|
|
24 V DC Power Consumption | 18 A at nominal output |
| 9.1 A at nominal output | 17.3 A at nominal output | |
|
|
|
|
| |
| 7.5 A driven at |
| 3.7 A driven at | 7.1 A driven at | |
|
|
|
|
| |
| 1.0 A no signal / 2.5 mA in | 1.1 A no signal / 2.5 mA in | 0.4 A no signal / 2.5 mA in | 0.6 A no signal / 2.5 mA in | |
|
| ||||
|
|
|
|
| |
Protection |
| High Temperature, Inrush Current Limiters, Short Circuit |
| ||
|
|
|
| ||
Cooling |
|
| |||
|
|
|
| ||
Ambient Temperature Limits |
| +5° C ... +40° C (40° F... 105° F) |
| ||
|
|
|
|
|
|
Safety Class |
|
|
| I |
|
|
|
|
| ||
Dimensions (WxHxD), mm |
| 483 x 132 x 345 mm, 19” / 3 HU |
| ||
|
|
|
|
| |
Installation Depth without Connectors |
|
| 340 mm |
| |
|
|
|
|
| |
Installation Depth including Connectors |
|
| max. 410 mm |
| |
|
|
|
|
|
|
Weight | 22.3 kg | 22.5 kg |
| 13.2 kg | 16.7 kg |
|
|
|
|
|
|
Color |
|
| anthracite |
| |
|
|
|
| ||
Optional |
| ||||
| NRS 90206 Pilot Tone Monitoring (for four amplifiers) | NRS 90222 Remote module (note: not supplied with the DPA | |||
| NRS 90207 | 4120/DPA 4140) |
| ||
| NRS 90227 Output Transformer (floating, balanced | monitor | NRS 90224 Pilot tone & | ||
| outputs) for DPA 4411 |
|
| supplied with the DPA 4120/DPA 4140) | |
|
|
|
| NRS 90225 Standard input module (note: not supplied with the | |
| Additional Version DPA 4411: |
|
| DPA 4120/DPA 4140) |
|
| DPA 4411N: DPA 4411 + NRS 90206 + NRS 90207 |
| NRS 90227 Output transformer (floating, balanced monitor | ||
|
|
|
| output) |
|
|
|
|
| Additional Version DPA 4140: |
|
|
|
|
| DPA 4140N: DPA 4140 + NRS 90222 + NRS 90224 | |
|
|
|
|
|
|
68