EARTHSTONE OVENS | 15 |
CLEARANCE INFORMATION FOR FACADES
1 inch minimum clearance to combustibles
Facade
Flue Collar
Models 90 and 110 - 6 inch diameter
Models 130 and 160 - 8 inch diameter
| Air gap must be sealed with a non | |
| combustible strip. e.g. Aluminum or s/s | |
36” | Any adjacent combustible floor which projects | |
in front of the oven opening must be a | ||
| ||
| minimum of 30 inches away from each side of | |
| the door opening and 36 inches from the front | |
| of the door opening. | |
| 30” | |
| On/off switch for gas burner | |
| Temperature gauge | |
1 inch minimum | Do not block the notch exhaust port or the | |
underside of the primary hood. | ||
clearance to | ||
| ||
combustibles |
| |
| Granite mantle | |
| Burner control box, for PAGW models only. Adequate | |
| clearance must be provided for air openings into the | |
| combustion chamber for servicing and proper | |
| operation. Minimum 24” x 24” located on the bottom half | |
| of the oven. Installing a sealed enclosure around the oven | |
| shell may also cause improper operation by starving the | |
| burner system of combustion air. Also the use of return air | |
| or other venting systems located within sealed enclosures | |
| which surround the oven may cause negative pressure. |
If this area is to be covered with a facade it must be of a