EAW DSA250 & DSA230 5 . 3 A C M a i n s P o w e r C o n n e c t i o n, 3.2 PowerCon Plug

Models: DSA250 & DSA230

1 44
Download 44 pages 2.28 Kb
Page 20
Image 20
Figure 5.3.2 PowerCon Plug
Maximum 25 ft / 8 m (for <2% voltage drop at peak input power)

GROUND

L

N

NEUTRIK

POWERCON

PLUG NAC3FA

Figure 5.3.2 PowerCon Plug

5 . 3 A C M a i n s P o w e r C o n n e c t i o n

This section details the requirements for the AC mains which is the AC power connection required by each DSA loudspeaker.

5 . 3 . 1 A C M A I N S S U P P LY

CAUTION: Read all cautionary notes concerning electrical power in Chapter 1.

Each DSA Series loudspeaker is rated for a particular nominal AC Mains voltage: 115 V or 230 V. Provide the loudspeaker with 50 Hz or 60 Hz AC Mains circuit capable of:

 

100 V to 120 V

220 V to 240 V

DSA230

4 A

2 A

DSA250

8 A

4 A

Before applying power, ensure that the AC Mains voltage matches the voltage rating on the loudspeaker.

DANGER: DO NOT APPLY 230 V MAINS POWER IF THE VOLTAGE RATING ON THE LOUDSPEAKER IS 115 V. IMMEDIATE AND CATAS- TROPHIC DAMAGE TO THE LOUDSPEAKER WILL RESULT AND MAY CAUSE A FIRE HAZARD, SERIOUS PERSONAL INJURY, OR DEATH.

5 . 3 . 2 A C M A I N S C A B L E

The supplied Neutrik PowerCon NAC3FCA plug mates with the Neutrik PowerCon NAC3MPA AC MAINS jack on the loudspeaker. Because of both varying installation and electrical code requirements, neither an AC Mains cable nor AC mains supply connection are supplied.

1.Supply and connect a 3-conductor power cable to the supplied PowerCon plug, ensuring a proper ground connection.

2.Supply and attach an appropriate connector for the AC Mains connection at the other end.

Recommended Power Cable

Conductor Gauge: 14 AWG / 2.5 mm (limited by PowerCon design)

Cable O.D.: 5 mm to 15 mm (limited by PowerCon design) Recommended

length:

NOTE: If the power cable is longer than 25 ft / 8 m the voltage drop will increase.

5 . 3 . 3 P O W E R O N / O F F

There is NO power on/off switch on DSA Series loudspeakers. The loudspeaker will be powered on (energized) when connected to an AC mains supply. The LED on the “Signal End” will flash rapidly for about 3 seconds when first powered on. This is normal and indicates the electronics are being initialized.