5 . 1 . 2 A U D I O S I G N A L C O N N E C T I O N
CobraNet™: Skip to Section 5.2 if using CobraNet™ for distribution of the audio and control signals.
Audio A or
Audio B:
Nominal level: 0 dBu / 0.775 V rms. Recommended Conductor Gauge:
24 AWG to 18 AWG / 0.2 mm to 1 mm
Audio A and
Audio B: As above but
5 . 1 . 3 C O M P U T E R C O N T R O L C O N N E C T I O N
CobraNet™: Skip to Section 5.2 if using CobraNet™ for distribution
of the audio and control signals.
Recommended Conductor Gauge:
24 AWG to 18 AWG / 0.2 mm to 1 mm
NOTES:
1.Do not combine
2.An
3.
5 . 1 . 4 DAISY CHAINING COMPUTER AND AUDIO SIGNALS WITHIN CLUSTERS WITH MULTIPLE LOUDSPEAKERS
NOTE: The Signal Link jacks carry both computer and audio signals. The cable between the Signal Link jacks must be wired as a standard Ethernet crossover cable. A cable wired as a standard Ethernet straight through cable will not work.
Crossover Cable Wiring
STANDARD END PINS | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
CROSSOVER END PINS | 3 | 6 | 1 | 4 | 5 | 2 | 7 | 8 |
1.Up to 1 ft / 0.3 m between adjacent over/under loudspeakers in a cluster: Supplied
Connect between unused Signal Link jacks (Neutrik EtherCon) on vertically adjacent ends of the loudspeakers.
2.Up to 2 ft / 0.6 m between adjacent
Connect between unused Signal Link jacks (Neutrik EtherCon) on horizontally adjacent ends of the loudspeakers.
AUDIO –
AUDIO + | SHIELD |
Figure 5.1.2 Audio A & Audio B
SIGNAL+ SHIELD
Figure 5.1.3 EIA-485 Connector
LINK CABLE
P/N 0005854
Figure 5.1.4 Linking < 1 ft / 0.3 m
17