the up/down enclosure orientation is

 

 

correct for the application.

Distorted sound

Failed internal component(s)

Using the DSAPilot’s Service Mode,

 

 

check the operation of each amplifier

 

 

and driver.

Distorted sound

Excessive levels

Using the DSAPilot, monitor the DSA

 

 

signal path to check for clipping

 

 

at all monitoring points.

Distorted sound

Bad input signal

Use a substitute amplifier and

 

 

loudspeaker to check the quality

 

 

of the input signal to the DSA

 

 

Series loudspeaker.

EIA-485

 

 

No computer communication

Incorrect PC set-up

Follow the instructions in the

 

 

DSAPilot Help File for setting up

 

 

communications between the PC

 

 

and the DSAPilot

No computer communication

Incorrect connections

Check that EIA-485 cabling to

 

 

both the computer and the

 

 

loudspeaker is wired correctly for

 

 

the +/- signal wires and cable shield.

No computer communication

Incorrect termination

Ensure that a termination is engaged

 

 

at the EIA-485 port at the computer

 

 

and the Terminate Switch is “ON” at

 

 

the loudspeaker at the farthest end of

 

 

the EIA-485 cable run. All other

 

 

Terminate Switches should be “OFF”.

No computer communication

Loudspeaker is powered off

Ensure the loudspeaker is powered on.

No computer communication or

Improper network

Ensure the EIA-485 cabling and

only with some loudspeakers

configuration

termination conforms to the notes

 

 

in Section 8.3.

No computer communication

Improper link connections

Ensure the EIA-485 only cabling

with some loudspeakers

between loudspeakers

and/or the supplied RJ-45 Signal

 

 

Link Cables are connected between

 

 

loudspeakers as detailed in this

 

 

manual.

CobraNet™

 

 

Audio signal or computer

Network cabling does

Ensure Ethernet cabling meets

communication not functioning

not meet specification

IEEE 802.3u specifications for

or not functioning correctly

 

100BASE-T networking.

Audio signal or computer

CM-1 Interface Card

Replace with a known good CM-1

communication not functioning

malfunctioning

Interface Card to determine if the

or not functioning correctly

 

removed card is faulty

Other CobraNet™ problems

Network or digital audio

Refer to either IEEE 100BASE-T or

 

not properly implemented

Peak Audio documentation to

 

 

troubleshoot network or digital

 

 

audio difficulties.