Ignition switch

STORAGE

LONG TERM STORAGE (Over 30 Days)

WARNING DANGER

DO NOT STORE IN AN ENCLOSURE WHERE FUEL FUMES MAY ACCUMULATE OR REACH AN OPEN FLAME OR SPARK.

Do not store your unit for a prolonged period of time (30 days or longer) without performing protective storage maintenance which includes the following:

1.Store unit in a dry, dust free place, out of the reach of children and other unauthorized persons.

2.Place ignition switch in “STOP” position.

3.Remove accumulation of grease, oil, dirt and debris from exterior of unit.

7.Remove the spark plug and pour 1/2 tablespoon of fresh, clean, two-stroke engine oil into the cylinder through the spark plug hole.

A.Place a clean cloth over the spark plug hole.

B.Pull the recoil starter handle 2 or 3 times to distribute the oil inside the engine.

C.Observe the piston location through the spark plug hole. Pull the recoil starter handle slowly until the piston reaches the top of its travel and leave it there.

8.Install the spark plug (Do not connect ignition cable).

4.Perform all periodic lubrication and services that are required.

5.Tighten all the screws, bolts and nuts.

6.Drain the fuel tank completely and pull the recoil starter handle several times to remove fuel from the carburettor.

NOTE

For future reference, you should keep this operator’s manual.

If this operator’s manual has become illegible through impairment or is lost, please purchase a new one from your ECHO dealer.

When renting or lending this machine to a person who will operate it, always include this operator’s manual, which provides explanation and instructions.

When transferring a product, please deliver it attaching the operator’s manual.

23

SRM-2305