12. TECHNICAL SPECIFICATIONS

 

 

Operating Voltage

: 230±10% VAC, 50Hz

Power

:

1 Watt (60 mA)

Power on Indicator

:

Green Light

Sensor

:

Electrochemical Sensor

CO Sensitivity

: Meets BS EN 50291: 2001.

 

 

Unit operates as per Table B (on page 8).

Electrical Safety

: Complies with relevant sections of EN 60335-1: 1994

Electromagnetic

: Complies with BS EN 50270

Compatibility

 

 

Test/Hush Button

: Checks electronics and horn.

 

 

When the unit is alarming, after sensing CO, pressing the Test/Hush button will immediately stop

 

 

the horn (the red light will continue to flash). If CO is still present the red light and the horn will turn

 

 

on again after about 4 minutes. The unit can only be silenced once during a CO incident. At 300

 

 

ppm CO the unit cannot be silenced. (With interconnected units, the Hush only works on the alarm

 

 

sensing CO).

Fast CO Test Mode

: Pressing the Test/Hush button also causes the unit to check for CO 4

 

 

seconds later to facilitate testing in CO gas. It gives 3 beeps and the red light

 

 

flashes to indicate the CO level if CO is sensed and then resets.