CO Alarm Memory:

: A unit will indicate if it has been in alarm previously by flashing the red light

 

for 2 seconds every 40 seconds (2 flashes for 50 ppm CO, 4 flashes for 100

 

ppm CO and 8 flashes, for 300 ppm CO). When the Test/Hush button is

 

pressed, the red light flashes (as per Table B on page 8) to indicate the

 

previous CO alarm level detected. The memory is cleared by holding down

 

the Test/Hush button until the red light stops flashing.

Digital Display

: Range 50 - 300ppm CO

(Ei261DENRC only)

Resolution 5 ppm CO

 

With low rechargeable cells - CP

 

With sensor faulty - SF

 

With Test/Hush button pressed - previous peak CO level

Dimensions

: 126 x 150 x 42 mm.

Weight

: 330g.

13.TROUBLESHOOTING

1.ALARM DOES NOT WORK WHEN THE TEST BUTTON IS PRESSED:

-Check that the green mains power light is on. If it is off check the wiring, fuse, circuit breakers etc.

-Hold the Test/Hush button down for at least 5 seconds.

2. ALARM BEEPS AND AMBER LIGHT FLASHES EVERY 40 SECONDS:

-If the alarm beeps and the amber fault light flashes every 40 seconds, the CO sensor is probably defective.