Installing a PCI Board

 

Remove

PCI

 

the cable is longer than necessary, connect it to the boards so that all the unused connectors are at one end of the cable.

Installing the CT Bus Cable

Pinout for RJ–14 Jacks on D/120JCT-LSU Bracket

 

 

6

 

 

6

Line 2

Earth Recall

 

 

5

 

 

 

5

Line 2

Ring

 

 

 

 

 

 

4

 

4

Line 1

Tip

 

 

Contacting Technical Support

Dialogic provides technical support for its products through a network of value added distributors who are trained to answer technical questions on installing and configuring Dialogic® products. If you

Dialogic products are not intended for use in medical, life saving, life sustaining, critical control or safety systems, or in nuclear facility applications.

It is possible that the use or implementation of any one of the concepts, applications, or ideas described in this document, in marketing collateral produced by or on web pages maintained by Dialogic may infringe one or more patents or other intellectual

Cover

Board

Colored

CT Bus

3

3 Line 1 Ring

are unsure how to contact your support channel,

property rights owned by third parties. Dialogic does not provide

Plate

Stripe

Cable

2

 

 

2 Line 2 Tip

1

 

 

 

 

 

 

please call Dialogic in the United States at 973-967-

any intellectual property licenses with the sale of Dialogic products other than a license to use such product in accordance with

Computer

Chassis

PCI Slot

ISA Slot

4.Insert the board's edge connector into the bus slot. Apply pressure only to the top edge of the board, and gently rock the board forward and backward to seat the edge connector into the slot.

5.Install the retaining screw.

6.If installing multiple boards, select a new slot and repeat steps 3 through 5 for each board you are installing.

Connecting the CT Bus Cable

For the D/120JCT-LSU board to interoperate with other telecom boards in the system, the boards must be interconnected using a cable. The D/ 120JCT-LSU board has an H.100 CT Bus connector, which may be directly connected to other CT Bus boards with an appropriate CT Bus cable. The D/ 120JCT-LSU board can also interconnect with SCbus boards by means of a CT Bus to SCbus adaptor.

A CT Bus cable is not included with the D/120JCT- LSU board. You must order an appropriate cable as an accessory item. CT Bus cables are available in a variety of configurations to accommodate different numbers of interconnected boards. Always use a cable that closely matches the number of boards you are actually using; avoid using a cable that is longer than necessary for your particular system. If

(Pin 1)

Note:

Your CT Bus cable may have a different number of connectors (drops).

Installing a CT Bus/SCbus Adapter

To connect a the D/120JCT-LSU board to one or more boards that are interconnected via SCbus, you must use an optional CT Bus to SCbus adapter. This adapter assembly is installed on the CT Bus board that is physically closest to the SCbus boards; only one adaptor is used per system.

Refer to the documentation shipped with the adaptor for more information on proper installation.

Completing the Installation

After installing all the boards required for your system and interconnecting them with appropriate cables, replace the cover on the computer to complete the installation.

5.Connecting to External Equipment

Each of the six RJ-14 jacks on the rear bracket of the the D/120JCT-LSU board supports two analog telephony channels. A standard telephone will not function when directly connected to the board.

Note: The RJ-14 jacks use 2 tip/ring pairs with 2 earth recalls, one for each channel.

1 Line 1 Earth Recall

6. After Installing the Board

After you install the D/120JCT-LSU board and any other Dialogic® boards, you can proceed with the following activities:

Installing the software - Install the Dialogic® system release software as described in the Software Installation Guide for your system release.

Configuring the software - Configure the system release software as described in the Configuration Guide(s) for your system release.

Testing the board - Test the D/120JCT-LSU board as described in the diagnostics documentation for your system release.

Troubleshooting problems - The administration and diagnostics guides for your system release provide information on troubleshooting problems.

For technical specifications and product information go to: http://www.dialogic.com/ products.htm.

7. Removing the Board

Removal of the board is a straightforward process. Remove the board using the reverse of the procedure described in Section 4, Installing the Board above.

8.Warranty and Return Information

Warranty Period

For specific warranty information for this board, refer to the Warranty section of the Products page, located at this URL: http://www.dialogic.com/ warranties/.

6600 (9am-5pm EST) and we will assist in obtaining the appropriate support channel.

Outside the United States please refer to http:// www.dialogic.com/support/contact to obtain local contact information. Dialogic also provides direct support via Dialogic® Pro™ Services agreements. For more details of direct support from Dialogic please refer to:http://www.dialogic.com/support/ DialogicPro

Returning a Product

To return a board for warranty repair or any other returns, please refer to the following: http:// www.dialogic.com/support/hwfaults.

9. Sales Assistance

If you have a sales question, please contact your local Sales Representative or the Regional Sales Office for your area. Address, telephone and fax numbers, are available at the Dialogic website located at: http://www.dialogic.com/contact.htm.

To purchase Dialogic® products, please refer to the following website to locate the appropriate supplier: http://www.dialogic.com/purchase.htm.

All contents of this document are furnished for informational use only and are subject to change without notice and do not represent a commitment on the part of Dialogic Corporation or its subsidiaries (“Dialogic”). Reasonable effort is made to ensure the accuracy of the information contained in the document. However, Dialogic does not warrant the accuracy of this information and cannot accept responsibility for errors, inaccuracies or omissions that may be contained in this document.

INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH DIALOGIC® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN A SIGNED AGREEMENT BETWEEN YOU AND DIALOGIC, DIALOGIC ASSUMES NO LIABILITY WHATSOEVER, AND DIALOGIC DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF DIALOGIC PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY.

intellectual property owned or validly licensed by Dialogic and no such licenses are provided except pursuant to a signed agreement with Dialogic. More detailed information about such intellectual property is available from Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada H4M 2V9.

Dialogic encourages all users of its products to procure all necessary intellectual property licenses required to implement any concepts or applications and does not condone or encourage any intellectual property infringement and disclaims any responsibility related thereto. These intellectual property licenses may differ from country to country and it is the responsibility of those who develop the concepts or applications to be aware of and comply with different national license requirements.

Dialogic, Diva, Eicon, Eicon Networks, Eiconcard, Dialogic Pro and SIPcontrol, among others, are either registered trademarks or trademarks of Dialogic. Dialogic's trademarks may be used publicly only with permission from Dialogic. Such permission may only be granted by Dialogic’s legal department at 9800 Cavendish Blvd., 5th Floor, Montreal, Quebec, Canada H4M 2V9. Any authorized use of Dialogic's trademarks will be subject to full respect of the trademark guidelines published by Dialogic from time to time and any use of Dialogic’s trademarks requires proper acknowledgement. The names of actual companies and products mentioned herein are the trademarks of their respective owners.

Page 2
Image 2
Eicon Networks D/120JCT-LSU Connecting to External Equipment, After Installing the Board, Removing the Board