■Optical Adjustments
Before taking optical adjustments below, remove the Cabinet Top and Main Board following to the “Mechanical Disassemblies”
Adjustments require a 2.0mm hex wrench and a slot screwdriver. When you adjust Condenser lens, Condenser
Note: Do not disconnect connectors K8N, K8P, K8H, K8R and K8S on the main board, because the projector can not turn on due to operate the power failure protection.
Contrast adjustment
[Before Adjustment]
- Input a 100% of black raster signal.
[R/G/B-CONTRAST ADJUSTMENT]
1 Loosen a screw A
2 Turn the polarized glass mounting base as shown in
3 Tighten the screw A to fix the polarized glass mounting base.
Repeat steps 1 to 3 for remaining polarized glasses.
A
Slot B
Polarized glass mounting base
Main Board
A
A
Mounting Base
A