Setting

Fan

This function provides the following options in the cooling fans’ operation when the projector is turned off (p.22).

L1....... Normal operation

L2....... Slower and lower-sound than the normal operation

(L1), but it takes more time to cool the projector down.

Fan control

Choose the running speed of cooling fans from the following options.

Normal ..... Normal speed

Max.......... Faster than the normal speed.

Warning log

This function records anomalous operations while the projector is in operation and use it when diagnosing faults. Up to 10 warning logs are displayed with the latest warning message at the top of the list, followed by previous warning messages in chronological order.

Note:

•When the Factory default function is executed, all the warning log records will be deleted.

Lamp counter

This function is used to reset the lamp counter.

When the lamp life is left less than 100 hours, the Lamp replacement icon (Fig.1) will appear on the screen, indicating that the end of lamp life is approaching.

When the lamp life is left 0 hour, the Lamp replacement icon (Fig.2) will appear on the screen, indicating that the end of lamp life is reached.

When replacing the projection lamp, reset the lamp counter. See "Resetting the Lamp Counter" on page 59.

Note:

•The Lamp replacement icons (Fig.1 and Fig.2) will not appear when the Display function is set to “Off” (p.46), during “Freeze” (p.27), or “No show” (p.27).

Fan

Fig.1 Lamp replacement icon

This icon appears on the screen when the end of lamp life is approaching.

Note:

•This icon also appears at turning on and selecting input source.

Fig.2 Lamp replacement icon

This icon appears on the screen when the end of lamp life is reached.

Note:

•At turning on, the icon (Fig.2) will appear. At selecting input source, the icon (Fig.1) will appear.

54

Page 54
Image 54
Eiki LC-XB29N owner manual Fan control, Lamp counter