DIP Switch Settings - BAUD RATE

Set the BAUD RATE DIP switch to the 9600 position (Up) when utilizing RS-232 con- trollers that require this baud rate. Use the 19.2k (Down) position for ELAN RS-232 applications and third party controllers that operate at 19.2k.

UNIT ID

RATE

 

UNIT 1

9.6KBAUD

UNIT 3

UNIT 2

 

 

/

UNIT 4

19.2K

 

1 2 3

9.6K BAUD

UNIT ID

RATE

 

UNIT 1

9.6KBAUD

UNIT 3

UNIT 2

 

 

/

UNIT 4

19.2K

 

1 2 3

19.2K BAUD

(Factory Default)

75 Ohm Termination DIP Switch Settings

There are eight 75 Ohm Termination DIP Switches used to optimize video signals when sharing sources with other devices or using multiple V883s. For each input that is shared using a ‘Y’ cable, place the corresponding DIP switch in the OFF/ DOWN position. When not sharing a source, the DIP switch should remain in the factory default ON/UP position.

Not Shared

Shared

Source

Source

75 OHM

INPUT

TERM

ON/UP OFF/DOWN

(Factory Default)