Elation Professional CMY Zoom 575 Lamp Installation Instructions, Installation Procedure

Models: CMY Zoom 575

1 52
Download 52 pages 61.93 Kb
Page 11
Image 11
5. LAMP INSTALLATION INSTRUCTIONS

CMY Zoom 575™

5. LAMP INSTALLATION INSTRUCTIONS

Installing or replacing the lamp

Only install the lamp with the device unplugged from the mains.

The lamp has to be replaced when it is damaged or deformed.

Before replacing the lamp, be sure the unit has had ample time to cool. To avoid self injury, never touch the lamp when it is hot.

During the installation of the discharge lamp do not touch the glass portion of the bulb with your bare hands. Always use a cloth to handle the lamps during insertion and removal.

Do not install lamps with a higher wattage than that specified by the manufacture, they generate higher temperatures than which the device is designed to cool and may explode.

Installation Procedure:

1.Lay the fixture on its’ back and remove the two Phillips screws labeled “A” and “B” found on the bottom plate of the fixture.

2.Gently pull out the lamp/socket assembly to access the lamp.

3.Gently remove the old lamp by grasping it by the ceramic base.

4.Carefully insert the new lamp into the socket (Only use a MSR 575/2 GX9.5 lamp or