MAINS OPERATION & RESULTING TEMPERATURE

PA2400T - 100V output Umains
[V]
Imains
[A]
Pmains
[W]
Pout
[W]
PD
[W]
BTU/
hr(3)
idle 230 0,3 44,3 0 44 151
Max. output power into 25ohms(1) 230 8,9 1643 2x430 783 2672
1/3 max. output power into 25ohms(1) 230 5,5 952 2x143 665 2270
1/8 max. output power into 25ohms(1) 230 3,7 602 2x54 495 1687
1/8 max. output power into 25ohms(2) 230 3,3 545 2x54 438 1493
1/8 max. output power into 25ohms(2) (4) 253 3,7 646 2x65 516 1760
Normal-Mode (-10dB) into 25ohms(1) 230 3,3 540 2x43 454 1549
Rated output power (0dB, rated) into 25ohms(1) 230 8,5 1550 2x400 750 2559
Alert-Mode (-3dB) into 25ohms(1) 230 6,3 1119 2x200 719 2453
PA2250T - 100V output Umains
[V]
Imains
[A]
Pmains
[W]
Pout
[W]
PD
[W]
BTU/
hr(3)
idle 230 0,2 31,6 0 32 108
Max. output power into 40ohms(1) 230 5,5 960 2x270 420 1433
1/3 max. output power into 40ohms(1) 230 3,5 571 2x90 391 1334
1/8 max. output power into 40ohms(1) 230 2,3 365 2x34 298 1015
1/8 max. output power into 40ohms(2) 230 2,1 330 2x34 263 896
1/8 max. output power into 40ohms(2) (4) 253 2,3 385 2x41 303 1035
Normal-Mode (-10dB) into 40ohms(1) 230 2,1 328 2x27 274 935
Rated output power (0dB, rated) into 40ohms(1) 230 5,4 929 2x250 429 1464
Alert-Mode (-3dB) into 40ohms(1) 230 4,0 668 2x125 418 1426
PA1250T - 100V output Umains
[V]
Imains
[A]
Pmains
[W]
Pout
[W]
PD
[W]
BTU/
hr(3)
idle 230 0,2 21,7 0 22 74
Max. output power into 40ohms(1) 230 2,8 487 1x270 217 740
1/3 max. output power into 40ohms(1) 230 1,8 289 1x90 199 679
1/8 max. output power into 40ohms(1) 230 1,2 182 1x34 148 506
1/8 max. output power into 40ohms(2) 230 1,1 170 1x34 136 465
1/8 max. output power into 40ohms(2) (4) 253 1,2 197 1x41 156 533
Normal-Mode (-10dB) into 40ohms(1) 230 1,1 164 1x27 137 467
Rated output power (0dB, rated) into 40ohms(1) 230 2,7 471 1x250 221 754
Alert-Mode (-3dB) into 40ohms(1) 230 2,0 339 1x125 214 730
(1)Sine wave 1kHz
(2)Pink noise acc. to EN60065
(3)1BTU = 1055.06J = 1055.06Ws
(4)10% mains over voltage
(5)PD = Power dissipation
The following factors allow direct proportional calculation of the mains current (Imains) for different mains

supply voltages: 100V = 2,3; 120V = 1,9; 220V = 1,05; 240V = 0,96

For power amp models with integrated transformers, the listed values for the 100V outputs are equally

applicable for the 70V, 50V and for the low-impedance outputs as long as the connected load is

equivalent as well.