Installation

Water inlet (cold water connection only)

Before connect-

 

ing the hose be

 

sure to fit the

 

mesh filter «A»

 

supplied as per

A

diagram.

 

Installation

 

should comply

 

with local water

 

authority and building regulations’ requirements.

Set the hose correctly by loosening the ring nut. After positioning the inlet hose, be sure to tighten the ring nut again to prevent leaks.

Do not connect to a hot water supply.

Water drainage

The appliance drain hose should hook into a standpipe, the hook in the drain hose is formed using the plastic “U-Piece” supplied. The standpipe should have an internal diameter of approximately 38 mm (see dia- gram) thus ensuring there is an air break between the drain hose and standpipe.

When discharging into a stand- pipe ensure that the top of the curve in the hose end is no more than 90 cm (35.4”) and no less than 60 cm (23.6”) above floor level.

3 pin

Max. 90 cm.(35.4")

Min.60 cm.(23.6")

The upright standpipe should have a mini- mum length of 30 cm (12”) from the bottom of the elbow to the top of the pipe (see dia- gram). Make sure that it is designed in such a way that the end of the drain hose cannot be covered with water.

Longer drain hoses are available in lengths of 2.7 and 4 metres from your AEG Service Force Centre.

Min. 30 cm.(12")

38mm.(1/2 ") diameter standpipe

47

Page 47