This appliance is designed to be installed with an appliance flexible connection only. Supply piping should not
be less that R³/8. Connection is made to the Rc ½ (½" B.S.P.) female threaded entry pipe located just below
the hotplate level on the rear left hand side of the appliance. NOTE: ONLY LIQUID SEALANTS TO BE
USED WHEN INLET GAS PIPE IS FITTED TO RESET VALVE I.E.: DO NOT USE P.T.F.E. SEALANT
TAPE.
Check for gas soundness after connecting the gas supply.
The gas bayonet connector must be fitted in the shaded area indicated in Fig. 4. Take into account that it
must be possible to pull the appliance forward sufficiently. The hose must not get caught on the stability
bracket.
IMPORTANT: FLEXIBLE TUBING USED MUST COMPLY WITH BS. 669 CURRENT EDITION.
L.P.G. FLEXIBLE CONNECTIONS MUST BE OF A TYPE SUITABLE FOR L.P.G. AND CAPABLE OF
OPERATION UP TO 50 mbar AND TO CARRY A RED STRIPE, BAND OR LABEL.

5. FITTING THE BATTERY

1. The battery is located on the left hand side of the front plinth and can be viewed through a slot in the
bottom left hand corner of the front frame( Fig 5.)
2. To gain access to the battery, open the main oven door, rotate the battery holder clockwise.
3. Fit the battery AA size ensuring the positive, + terminal is on the right hand side as shown in the
diagram. Return the battery to original position by turning it anti-clockwise.

6. PRESSURE TESTING

39
G R O S V E N O R
Fig.5
200

400 650

250
Fig.4