53/64"53/64"
21 mm | K | 21 mm |
|
|
137/64"
40 mm
B.2.3 REVERSING OPENING OF THE DOOR
These cabinets are normally supplied with opening to the right. When changing direction of opening so that the door opens from left to right, proceed as follows:
•disconnect from the power supply;
•remove lower bracket “H” (Detail 2);
•remove the door and remove component “G” (Detail 2);
•unscrew the two fixing bolts from bracket “E” and the screw which secures hinge “F” (Detail 1);
•turn the door and fit component “G” and hinge “F” on the opposite side;
•fix upper hinge “E” on the left hand side of the cabinet;
•refit lower bracket “H” on the opposite side of the cabinet;
•fit the door onto lower hinge “H”;
•fix bracket “E” to the structure by screwing down the fixing bolts;
•reconnect the power supply.
B.2.2ELECTRICALCONNECTION
When making the electrical connection, carefully comply with the information on the dataplate.
The appliance works on 120V/1ph/60Hz.
CAUTION:
Connection to the electrical mains must be carried out in accordance with current regulations and the standards re- quiredbytheNationalElectricCode(NEC),knownasNFPA70.
Please check:
Connection to the main power must be carried out in accord- ance with binding rules and standards.
Before connecting, make sure that:
-The line cord has an efficient grounding connection and the main power frequency corresponds to that stated on the data plate. If you have doubts on the efficiency of the grounding connection have the circuit checked by a qualified technician.
-The appliance must be connected to the main power with a permanent connection.
-In order to protect the appliance from possible overloads or
-After making the connection and with the appliance running, check that the rated level does not fluctuate by ± 10%.
The connection must be made with cable of a suitable for am- perage and voltage.
The manufacturer will accept no liability for any damage or injury resulting from the violation of the above rules or of the current electrical safety standards in the country where the appliance is used.
E
F
(Dett.1)
G
H
(Dett.2)
12