starting and ending time and date of the alarm are shown by a rolling label: “TEMP 78.8F/26C Start 17.05
To have access to recorded HACCP alarms press
HACCP
button for 4 seconds; now the display visualizes
HISt and then AL_1 (symbol of the alarm); this shows the last maximum chamber temperature alarm stored in the PCB.
| HACCP |
Press | button to visualize the value of last |
maximum chamber temperature alarm. Now in the display we visualize:
-TEMP 78.8F/26C (type and value of maximum chamber temperaturealarm)
-Start time and date (starting date and time of alarm)
-End time and date (ending date and time of alarm)
| HACCP |
|
Press | button to return to visualize the symbol of | |
|
| HACCP |
the alarm (AL1). Press | button to visualize the |
next maximum chamber temperature alarm. If nothing is pressed within 10 seconds we go out from HACCP section.
·HOW TO CHECK THE OLD ALARMS?
| HACCP |
Keep pressed the button | : the display shows |
AL1 (the last alarm); to select all the other alarms (AL2, AL3, ...)
press .
·HOW LONG ARE THE ALARMS RECORDED?
Forever, or better, until the memory is out of space (maximum number of recorded alarms: 99).
C.1.7.3 SERVICE ALARMS
To have access to SERVICE ALARMS press
button for 4 seconds; now the display visualizes the first SERVICE ALARM stored in the electronic board, for example
“b1” (door open). Press the button to visualize
the next SERVICE ALARM stored in the electronic board. If the electronic board has not stored other SERVICE ALARMS, the display visualizes
we go out from SERVICE ALARMS.
·HOW LONG ARE THE ALARMS RECORDED?
Until you have seen the complete alarms list recorded. After that, they will remain stored ‘till a new alarm occurs: the reset will be automatic.
·HOW TO FIND AN ALARM? - blinking led of alarm button - buzzer ON (sound alarm)
·HOW TO CHECK THE ALARMS?
Keep pressed the button : the display is showing
the last alarm (a label) occured and the buzzer is going OFF. In
order to reset the alarm, press | until the display | |||
shows |
|
|
| |
C.1.7.4 SERVICE ALARMS LIST |
|
| ||
· Type “b” service alarms |
|
| ||
|
|
|
|
|
| b1 | Door is open |
|
|
| Microswitch is broken |
| ||
|
|
| ||
| b2 | Reset HACCP memory |
| |
|
|
|
| |
| b3 | The condenser is dirty |
| |
| Condenser fan is broken |
| ||
|
|
| ||
| b4 | Missing supply |
|
|
| Wrong plug positioning |
| ||
|
|
| ||
· Type “E” service alarms |
|
| ||
|
|
| ||
| E1 | Sensor |
| |
|
|
|
| |
| E2 | Sensor is broken or disconnected |
| |
|
|
|
| |
| E3 | Sensor |
| |
|
|
|
| |
| E4 | Sensor is broken or disconnected |
| |
|
|
|
| |
| E5 | Sensor |
| |
|
|
|
| |
| E6 | Sensor is broken or disconnected |
| |
|
|
|
| |
| E7 | Sensor |
| |
|
|
|
| |
| E8 | Sensor is broken or disconnected |
| |
|
|
|
| |
| E9 | Low chamber temperature |
| |
|
|
|
| |
| E10 | Low evaporator temperature |
| |
|
|
|
|
|