After 60 seconds, you can remove the safety device on the burner by touching both the
Increasing Controls and the Decreasing
Control at the same time.
Then, follow the instructions given in the paragraph “How to light a burner”.
Caution! Check that the burner cap and crown are correctly positioned (see diagram).
If the ignition problem persists, refer to chapter “Something not working”.
Never use a manual spark
In case of accidental extinguishing (automatic reignition)
If the burner flame is accidentally extinguished (draughts, spilling of liquids, etc.), the gas flow is immediately interrupted.
After about 20 seconds, the ignition device automatically repeats the ignition procedure.
Upon reignition, the burner flame is first set at maximum level, then it is automatically adjusted to the level set before it was accidentally extinguished.
If three consecutive reignition attempts fail, a safety device is set on the burner. The flame level indicators and the residual heat indicator flash.
Caution! When the safety device is set on a burner, the burner controls cannot be operated for about 60 seconds.
After 60 seconds, you can remove the safety device on the burner by touching both the
Increasing Controls and the Decreasing
Control at the same time.
Then, follow the instructions given in the paragraph “How to light a burner”.
10
Burner |
Cap |
Burner |
crown |
Spark |
plug |
Thermo- |
couple |