Upon completion there must be no cut, or stray strands of wire present and the cable clamp must be secure over the outer sheath.
A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut off plug is disposed of safely.
Permanent Connection
In the case of a permanent connection, it is necessary that you install a double pole switch between the hob and the electricity supply (mains), with a minimum gap of 3 mm. between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations.
The switch must not break the yellow and green earth cable at any point.
Ensure that the hob supply cable does not come into contact with surfaces with temperatures higher than 50 deg. C.
Supply cable replacement
The cable used to connect the hob to the electrical supply must comply to the specifications given below.
Min. size Cable/flex | Cable / flex type | Fuse |
|
|
|
0.75 mm2 | H05 | 3 A |
|
|
|