8
II. By connecting the cooker point to the hob
and then connecting the hob to the oven.
Provided that the hob manufacturer permits
it, connect the oven to the hob to the cooker
point using the same cabling as described in
(a) above. Check the hob terminal block is
large enough to take two cables and is of
suitable rating. If not b) i) on page 7 must be
used. See Fig.2.
NOTE: 13 amp cable is not suitable for connecting
this application.
NOTE: It is good practice to:
· Fit an Earth Leakage Circuit Break er to your
house wiring
· W ire your appliance to the latest IEE regulations.
PREPARING CABINET FOR FITTING OF OVEN
· Make sure the cabinet is the correct size for the
appliance to be fitted (Ref. Fig. 3 and 4).
· If the size is between 565-570mm, then the
cabinet should be modified so that at the scr ew
fixing points the recommended dimension of at
least 560-565mm is maintained. The
modification should ideally be localised t o ensure
that after screw fitment the oven is securely
fixed into position.
· The cabinet must be stable and level by firmly
securing it to the wall or floor. If necessary,
make arrangements to ensure the shelf upon
which the oven will rest is level.
Fig. 2