OPERATING YOUR HOOD

The hood is operated using the slide controls under the front edge of the hood. The light switch turns the halogen lights on and off.

LIGHTBLOWER BLOWER

SWITCHSPEED ON/OFF

CONTROL SWITCH

PILOT

LAMP

Figure 1

The blower on/off switch turns the blower on to the running speed set by the blower speed control. The blower must be turned on and off using this switch.

The blower speed control changes the running speed of the blower (1-2-3).

The pilot lamp lights up whenever the blower is on.

Auto-Start Heat Sensing System

Your hood is equipped with an Auto-Start Heat Sensing System thermostat. This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface.

1If blower is OFF - it turns blower ON to HIGH speed.

2If blower is ON at a lower speed setting - it turns blower up to HIGH speed.

When the temperature level drops to normal, the blower will return to its original setting.

OPERATING YOUR HOODWARNING

The Auto-Start Heat Sensing System thermostat can start the blower even if the hood is turned OFF. When this occurs, it is impossible to turn the blower OFF with its switch. If you must stop the blower, do it from the main electrical panel.