Always use a correctly installed shock- proof socket.

Make sure that there is an access to the mains plug after installation.

Do not pull the mains cable to disconnect the appliance. Always pull the mains plug.

The appliance must not be connected with an extension cable, an adapter or a multiple connection (risk of fire). Check that the ground connection is in conform- ity with the standard and regulations force.

The power cable must be placed in such a way that it does not touch any hot part.

Connect the appliance to the mains with a device that lets to disconnect the appli- ance from the mains at all poles with a contact opening width of minimum 3 mm, eg. automatic line protecting cut- out, earth leakage trips or fuse.

None of a parts of the connection cable can not get a temperature 90°C.

Electrical Requirements

Any permanent electrical installation must comply with the latest I.E.E. Regulations and local Electricity Board regulations. For your own safety this should be undertaken by a qualified electrician, e.g. your local Electricity Board, or a contractor who is on the roll of the National Inspection Council for Electrical Installation Contracting (NICE- IC).

The manufacturer declines any liability should these safety measures not be observed.

This hob is designed to be connected to a 230 V 50 Hz AC electrical supply.

Before switching on, make sure the elec- tricity supply voltage is the same as that in- dicated on the hob rating plate. The rating plate is located on the bottom of the hob. The hob is supplied with a 3 core flexible supply cord incorporating a 3 amp plug fit- ted. In the event of having to change the fuse, a 3 amp ASTA approved (BS 1362) fuse must be used.

12

3

4

5

1Green and Yellow

23 amp fuse

3Brown

4Cord clamp

5Blue

Should the plug need to be replaced for any reason, the wires in the mains lead are coloured in accordance with the following code:

Green and Yellow

- Earth

Blue- Neutral

Brown- Live

1.Connect the green and yellow (earth) wire to the terminal in the plug which is marked with the letter 'E' or the earth

symbol Manual background or coloured green and yel- low.

2.Connect the blue (neutral) wire to the terminal in the plug which is marked with the letter 'N' or coloured black.

3.Connect the brown (live) wire to the ter- minal in the plug which is marked with the letter 'L' or coloured red.

Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.

Important! A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut off plug is disposed of safely.