Blower Motor Systems Installation

11

 

 

previously removed. If it is removed, reattach the motor electrical plug to the connector on the blower motor assembly.

Complete Preparation

1.Determine and make all necessary cuts for the vent system.

IMPORTANT: When cutting or drilling into the ceiling or wall, do not damage electrical wiring or other hid- den utilities.

2.Determine the location where the ½” (1.3 cm) wiring conduit will be routed through the ceiling or wall between the remote blower and the hood insert.

3.Drill a 1¹⁄4” (3.2 cm) hole at this location.

4.Locate the electrical terminal boxes in the remote blower housing and hood insert (see “Complete Preparation” in the “Prepare Location” section). Remove the terminal box covers and set the covers and screws aside.

B

A

A. Electrical terminal box

B. Electrical knockout

5.Remove the electrical knockout from the remote blower housing and hood insert (see “Preparation” in the “Prepare Location” section) to prepare for the installation of the UL listed or CSA approved ½” (1.3 cm) wiring conduit and conduit connector. NOTE: Strain relief conduit are supplied with remote blower hardware.

6.With the hood insert mounted (see the “Install Hood Insert” section), run the ½” (1.3 cm) wiring conduit between the remote blower motor housing and the hood insert. Pull enough ½” (1.3 cm) wiring conduit to allow for easy connection to the terminal boxes in the remote blower housing and hood insert.

7.Run the six 18 AWG wires through the 12” (1.3 cm) wiring conduit and conduit connectors and into the terminal boxes on the remote blower housing and hood insert. Leave enough wire length in each terminal box to make the wiring connections.

8.Install the conduit connectors and conduit to the remote blower housing and hood insert electrical terminal boxes.

NOTE: Strain relief conduit are supplied with remote blower hardware.

9.Connect the vent system to the hood insert and remote blower motor system. Use clamps at all

joints. Use furnace duct tape to seal all joints tightly.

A

B

C

E

D

 

A. Vent System

 

B. Remote Blower Motor

 

C. Ceiling

 

D. Roof rafters / Plywood

 

E. Remote Blower Wiring

F

Conduit

 

F. Hood Insert Wiring

G

Conduit

G. Hood Insert

 

Make Electrical Connections for Remote Blower Motor System

Electrical Shock Hazard Disconnect power before servicing.

Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.

Electrical Connection Inside Remote Blower System

1.Disconnect power.

2.Connect the wires from the wiring conduit to the wires from the motor electrical plug cable inside the remote blower housing terminal box.

C D B

E

F

G H

A

I

A.UL listed or CSA approved

E. Red wires

12” (1.3 cm) wiring conduit

F. Blue wires

B.UL listed wire connectors

G. Gray wires

C.Black wires

H. Green (or yellow/green) and

D.White wires

green/yellow wires

 

I.Motor electrical plug cable

Page 11
Image 11
Electrolux EI30HI55KS, EI36HI55KS manual Complete Preparation, Joints. Use furnace duct tape to seal all joints tightly

EI30HI55KS, EI48HI55KS, EI36HI55KS specifications

The Electrolux EI36HI55KS, EI48HI55KS, and EI30HI55KS are three exceptional models from Electrolux's line of refrigerators that combine cutting-edge technology with user-friendly features, making them ideal additions to modern kitchens.

The EI36HI55KS is a standout model that offers a spacious 36-inch width and a sophisticated design. This refrigerator is equipped with TwinTech Freshness Control, ensuring both the refrigerator and freezer compartments maintain optimal humidity levels. This technology keeps fruits and vegetables fresh longer, preventing spoilage and waste. The model also features a total frost-free system, eliminating the hassle of manual defrosting while maintaining constant temperature and humidity in the fridge. With a sleek stainless-steel finish, it enhances the aesthetic appeal of any kitchen.

The EI48HI55KS model offers a larger 48-inch width, making it perfect for larger households or those who appreciate extra storage space. This unit also features the advanced TwinTech Freshness Control technology, ensuring that ingredients stay fresh while also providing a dedicated crisper drawer for fruits and vegetables. Additionally, it comes with a customizable temperature control system, allowing users to select the exact temperature for specific food items. The ice maker and water dispenser add convenience for those who enjoy chilled beverages, and the energy-efficient design ensures that it doesn’t add significantly to household energy bills.

The EI30HI55KS is a more compact model at 30 inches, making it an ideal choice for smaller kitchens without sacrificing functionality. This refrigerator also embraces the TwinTech Freshness Control system and features an attractive stainless-steel finish. The adjustable shelving system allows users to optimize their storage, while the efficient LED lighting illuminates the interior, making it easy to find ingredients. Its sleek and modern design fits seamlessly into any kitchen decor.

In summary, the Electrolux EI36HI55KS, EI48HI55KS, and EI30HI55KS refrigerators are all excellent choices for consumers seeking quality and innovation. With features such as TwinTech Freshness Control, customizable temperature settings, and energy-efficient designs, these models cater to a wide range of needs. Whether you require a spacious family-sized unit or a compact refrigerator for a smaller space, Electrolux has a solution that delivers on both performance and style.