Electrical Connection

The oven is designed to be connected to 230-240V~(50Hz) electricity supply.

The oven has an easily accessible terminal block which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

E - Earth terminal

1This oven must be earthed!

The cable used to connect the oven to the electrical supply must comply to the specifications given below.

For UK use only

Connection

Min. size

Cable/flex

 

Fuse

via

Cable/flex

type

 

 

 

 

 

 

 

 

• 13 A

2,5 mm2

3 core butyl

13

A min.

socket outlet

 

insulated

 

 

• 13 A

 

 

 

 

spur box

 

 

 

 

 

 

 

 

 

• Cooker Control

2,5 mm2

PVC/PVC

15

A min.

Circuit

 

twin and earth

20

A max.

 

 

 

 

 

It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm

between the switch contacts and of a type suitable for the required load in compliance with the current regulations.

The switch must not break the yellow and green earth cable at any point.

Important

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 50°C above the ambient tem- perature.

Before the oven is connected, check that the main fuse and the domestic installation can support the load; and that the power supply is properly earthed.

The manufacturer declines any responsibility should these safety measures not be carried out.

40

Page 40
Image 40
Electrolux EOB5665 manual Electrical Connection, This oven must be earthed, Type