Electrolux FKCH17F7HW service manual Condenser Service

Models: FKCH17F7HW

1 63
Download 63 pages 40.34 Kb
Page 46
Image 46

Component Teardown

Condenser Service

The condenser is foamed in place and is not accessible for repair. However, repair can be made by installing a service replacement condenser kit. Refer to the part list of the model being serviced for the correct kit part number.

Each service replacement condenser kit consists of a condenser assembly that can be installed on the back of the cabinet, mounting hardware, replacement filter-drier and a complete installation instructions.

To install, use the following procedure:

1.Disconnect unit from source of power.

2.Recover refrigerant by using EPA approved recovery system.

3.Installed the replacement condenser in accordance with the instructions included with the kit.

4.Evacuate and charge a system using the recommended procedure described under evacuation and recharging found in section 4.

4-14