Electrolux FKGHS01P manual VentingRequirements, Dryer gas pipe, Burner input requirements

Models: FKGHS01P

1 68
Download 68 pages 39.87 Kb
Page 8
Image 8

In Canada:

An individual manual shutoff valve must be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. It is recommended that an individual manual shutoff valve be installed within six (6) feet (1.8 m) of the dryer.

The location should be easy to reach for opening and closing.

A C E

Dryer gas pipe

The gas pipe that comes out through the rear of your dryer has a ³⁄₈" male pipe thread.

B

*6¼"

(15.9 cm)

BD

A. ³⁄₈" flexible gas connector

B. ³⁄₈" pipe to flare adapter fitting

C. ¹⁄₈" NPT plugged tapping

D. ½" NPT gas supply line

E. Gas shutoff valve

Gas supply connection requirements

There are many methods by which your gas dryer can be connected to the gas supply. Listed here are some guidelines for two different methods of connection.

Option 1 (Recommended method)

Flexible stainless steel gas connector:

If local codes permit, use a new flexible stainless steel gas connector (Design Certified by the American Gas Association or CSA International) to connect your dryer to the rigid gas supply line. Use an elbow and a ³⁄₈" flare x ³⁄₈" NPT adapter fitting between the stainless steel gas connector and the dryer gas pipe, as needed to prevent kinking.

Option 2 (Alternate method)

Approved aluminum or copper tubing:

Lengths under 20 ft (6.1 m) can use ³⁄₈" approved tubing (if codes and gas supplier permit).

If you are using natural gas, do not use copper tubing.

³⁄₈" flare x ³⁄₈" NPT adapter fitting between dryer pipe and ³⁄₈" approved tubing.

Lengths over 20 ft (6.1 m) should use larger tubing and a different size adapter fitting.

If your dryer has been converted to use L.P. gas, ³⁄₈" L.P. compatible copper tubing can be used. If the total length of the supply line is more than 20 ft (6.1 m), use larger tubing.

NOTE: Pipe joint compounds that resist the action of L.P. gas must be used. Do not use TEFLON®† tape.

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

A

 

1½"

 

(3.8 cm)

 

A. ½" NPT gas supply line

B. ³⁄₈" NPT dryer pipe

*NOTE: If the dryer is mounted on a pedestal, the gas pipe height must be an additional 13" (33 cm) from the floor.

Burner input requirements

Elevations up to 10,000 ft (3,048 meters):

The design of this dryer is certified by CSA International for use at altitudes up to 10,000 ft (3,048 m) above sea level at the B.T.U. rating indicated on the model/serial number plate. Burner input adjustments are not required when the dryer is operated up to this elevation.

Elevations above 10,000 ft (3,048 meters):

When installed above 10,000 ft (3,048 m) a 4% reduction of the burner B.T.U. rating shown on the model/serial number plate is required for each 1,000 ft (305 m) increase in elevation.

Gas supply pressure testing

The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than ½ psi.

VentingRequirements

WARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

4" (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFE™ vent products are recommended.

DURASAFE™ vent products can be purchased from your dealer or by calling Whirlpool Parts and Accessories. For more information, see the “Assistance or Service” section of this manual.

8

Page 8
Image 8
Electrolux FKGHS01P manual VentingRequirements, Dryer gas pipe, Burner input requirements, Gas supply pressure testing

FKGHS01P specifications

The Electrolux FKGHS01P is a highly regarded kitchen appliance that brings together innovation, design, and functionality. This cooking device is not just a standard kitchen appliance; it epitomizes modern cooking technology, ensuring a seamless culinary experience.

One of the main features of the FKGHS01P is its advanced induction cooking technology. Induction cooktops are known for their quick heating capabilities, and the FKGHS01P excels in this category. Induction cooking works by generating heat directly in the cookware through electromagnetic energy, which can reduce cooking times significantly. This also translates to increased energy efficiency as it wastes less heat than traditional gas or electric cooktops.

The appliance boasts a sleek and contemporary design, which makes it an attractive addition to any kitchen. Its smooth surface is easy to clean, and the minimalistic aesthetic fits well with modern kitchen decor. With intuitive controls, users can easily adjust cooking temperatures and settings, providing a user-friendly cooking experience.

Another standout feature of the Electrolux FKGHS01P is its versatile cooking zones. The induction cooktop includes multiple cooking zones of varying sizes, allowing users to accommodate a range of pot and pan sizes. Whether you're boiling pasta or simmering sauces, there is enough room to cook multiple dishes simultaneously.

Equipped with safety features, the FKGHS01P includes child lock settings and automatic shut-off systems, providing peace of mind for families. Furthermore, the induction technology allows for quick temperature adjustments, enhancing control over cooking processes and reducing the risk of burns or accidents.

In terms of smart technology, the Electrolux FKGHS01P integrates seamlessly with smart home systems, enabling connectivity and convenience. Users can monitor their cooking from a mobile device, receive notifications, and even manage timers remotely.

In summary, the Electrolux FKGHS01P offers a blend of state-of-the-art technology, safety, and sleek design. With its induction cooking capabilities, versatile zones, and smart home integration, it caters to both novice cooks and culinary enthusiasts alike. Its commitment to efficiency and user-friendliness makes it a standout appliance in the contemporary kitchen landscape.