DIRECT VENT INSTALLATION INSTRUCTIONS

DIRECT VENT INSTALLATION INSTRUCTIONS

PVVK-24H and PVVK-48H Vent Kit available from Empire Comfort Systems, Inc.

Note: Do not glue intake or exhaust pipes to Direct Vent Adaptor for serviceability.

MANTEL  EXHAUST OPENING MUST

Direct Vent System Building Exterior View EXHAUST OPENING MUST

BE POINTED DOWNWARD.

SURROUND

DO NOT GLUE

Figure 34

 

THIS POINT

 

 

Direct Vent System Building Exterior View

 

DIRECT VENT KIT

 

 

MODEL #PVVK-24H OR PVVK-48H

 

 

FLUE CENTER

 

 

12” (30.5cm)

 

 

MIN.

 

GAS SUPPLY

EXTERIOR GRADE

 

 

Figure 32

 

 

Horizontal Venting

 

45° ELBOW

 

47.5”

 

(1.2m)

47.5”

Figure 35

Maximum Horizontal Venting - 47 1/2” (1.2m)

(1.2m)

Minimum Horizontal Venting - 4 1/2” (11.4cm)

 

Figure 33

Horizontal Venting Maximum 47.5” (1.2m) with a 3”, 45° elbow 3”, 45° elbow can be purchased from a local hardware store

Page 30

22618-12-0707