OPTIONAL CONTROLLERS

 

 

 

MODELS

 

 

FRBTP

Battery Operated Remote w/ Programmable Thermostat

FRBTC

Battery Operated Remote w/ Thermostat

 

 

TRW

Battery Operated Wireless Remote Wall Thermostat

TMV2

Thermostat, 2 Stage

See your Mantis dealer for correct controller type.

INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION Installation Instructions for FRBTP, FRBTC, and TRW

The Remote Control FRBTP, FRBTC and TRW are all battery operated devices, which require a small amount of low voltage wiring. Begin installation by unplugging the unit and removing the front louver panel.

Remove blue jumper wire from junction block and save for future use. Using wire provided in the Mantis Owner’s Manual Package, connect remote wires using below schematic.

Black or white wire can be inserted in either remote control receiver connection hole. There is no polarity at this connection.

REMOTE

CONTROL RECEIVER

BLUE

BLACK

 

JUMPER WIRE

 

(TO BE REMOVED)

WHITE

 

 

 

WHITE

JUNCTION

C W2 W1 R

 

 

 

 

BLOCK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLUE

 

 

 

TRANSFORMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

TO “T1” (FRONT BURNER)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

TO “T2” (REAR BURNER)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHITE

 

 

 

 

 

 

 

TO “T1”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLUE

 

 

 

 

TO “T2”

 

 

 

 

 

 

 

 

 

 

Figure 49

 

 

 

 

Replace front louver panel and plug unit into outlet. Turn both burner switches to the ON position. Burner switches must remain in the ON position for remote to function. Set remote from the instructions provided with the remote control.

Note: When the heater or the Remote Control will not be used for long periods the burner switches should be in the OFF position, also in summer the heater should be turned off at the power point.

Installation Instruction for TMV2 - Two Stage Thermostat Model:

Begin installation by unplugging the unit and removing the front louver panel.

Determine mounting location of thermostat. Using standard 18 AWG wire, run four (4) strands of wire into rear of Mantis (See Figure 50) to junction block. Cut wire to correct length. Remove blue jumper wire from junction block and save for future use. Connect four (4) new thermostat wires to Mantis using schematic. See Figure 51.

Page 42

Figure 50

22618-12-0707

 

Page 42
Image 42
Elitegroup PV-28SV50-(BN,BP)-1 Optional Controllers, Installation Instruction for TMV2 Two Stage Thermostat Model