DIRECT VENT INSTALLATION INSTRUCTIONS (cont.)

DIRECT VENT INSTALLATION INSTRUCTIONS (cont.)

Installation on Rugs and Tile

If this appliance is to be installed directly on carpeting, tile, or other combustible mate- rial, other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.

The base referred to above does not mean

the fire-proof base as used on wood stoves. FLOOR PROTECTION The protection is primarily for rugs that may

be extremely thick and light-color tile that can discolor.

1 1/4”

1 1/4”(3.2cm) EXTERIOR GRADE

MIN.

FLUE CENTER

12”

(30.5cm)

MIN.

EXTERIOR GRADE

Figure 36

Minimum Exterior Grade Dimension - Unit Without Pedestal

1 1/4”

FLOOR PROTECTIONMIN. NO HEARTH REQUIRED (3.2cm)Manual background

MIN.

FLUE CENTER

12”

(30.5cm)

FLOOR PROTECTIONMIN. NO HEARTH REQUIRED

EXTERIOR GRADE

Figure 37

Minimum Exterior Grade Dimension - Unit With Pedestal

FLUE CENTER

12”

(30.5cm)

MIN.

EXTERIOR GRADE

Figure 38

Minimum Exterior Grade Dimension - Existing Fireplace Installation

22618-12-0707